Energy efficient architecture and regulations compliance with FenestraPro for Revit

How to ensure energy regulations compliance in Norway with FenestraPro for Revit?

TEK17 is the latest Technical Building Works Regulations in Norway. The Technical Building Works Regulations govern the properties and qualities that are mandatory for building works to be erected legally in Norway. Among many, the Technical Building Works Regulations set out requirements concerning the energy efficiency levels that must be met in the finished building works.

TEK17 addresses energy efficiency in building both through requirements on building’s total net energy consumption as well as the requirements on the elements’ minimum U-values.

According to TEK17, the general energy efficiency requirements are set according to the following principles:

Buildings shall be designed and constructed such that satisfactory energy performance is facilitated.
The energy requirements apply to the building’s heated gross internal area (BRA).
U-values shall be calculated as the mean for the various elements of the building.

While TEK17 requires detailed whole-building energy calculations to demonstrate compliance with maximum total net energy requirements, complementary and alternative prescriptive guidance is also provided. This means that considerations can be addressed from the earliest point in the design process and the building can be optimized.

How to account for energy efficiency in the design process?

While TEK17 requires detailed whole-building energy calculations to demonstrate compliance with maximum total net energy requirements, complementary and alternative prescriptive guidance is also provided. This means that considerations can be addressed from the earliest point in the design process and the building can be optimized.

Requirements to establish and calculate end energy are such that it often happens late in the design process.  In order to minimize late stage redesign to address issues highlighted when the whole building energy analysis is carried out, it is appropriate to consider the design of the façade in conjunction with other prescriptive guidelines provided by TEK17 on thermal performance and daylight factors.

These two performance characteristics need to be considered in conjunction with understanding passive solar heat gain to maximize heat gains to reduce heating loads, while also ensuring that the building doesn’t overheat to minimize cooling loads. And let’s take a look how FenestraPro allows for management of all of these factors.

How to manage thermal performance for energy efficiency in FenestraPro?

TEK17 provides a prescriptive guidance to demonstrate compliance with the Energy requirements. These requirements include energy saving measures such as thermal performance standards for building elements for different building categories (Section 14-2 (2), 14-3 & 14-5) and in some cases includes limitations on the proportion of windows and doors to be used.

FenestraPro for Revit facilitates compliance checking with regards to these thermal performance requirements. It can also be used to establish the maximum percentage glazing from the earliest stages in the design process through to later stage detail design.

Image 1 below shows how the required standards can be set for conceptual models within FenestraPro for Revit, and shows where values that “non-compliant” with the selected standard are highlighted as red.

Image 2 below highlights where thermal performance values are not specified in the detailed model and provides a link to adjust the analytical properties for the element and displays where the thermal performance values are not compliant with the selected standard or code.

How to manage natural daylight with FenestraPro for Revit?

In accordance with TEK17 section 13-7 daylight requirements can be fulfilled by ensuring that the average daylight factor in the room be at least 2.0%.
FenestraPro for Revit provides real time daylight factor values for every room within a building that enables compliance checking based on a 2% minimal design daylight factor. It considers the area of glazing, impact of shading devices, surrounding buildings and self-shading, and the glazing specification with appropriate Visible Light Transmittance (VLT).

Image 3 above shows how FenestraPro for Revit provides real time Design Daylight Factors for facades broken into various surfaces based on internal zoned spaces or rooms. Although the average design daylight factor for the façade is 3.89% the surfaces with minimal punched windows are below the required 2%, while the highly glazed areas at the curtain wall are in excess of 11.9% as these zones are almost 100% glazed. In this example it is required to increase the amount of glazing to the 3 surfaces that are below the minimum requirement.

How to manage Passive Solar Heat Gain in FenestraPro for Revit?

As described above TEK17 provides for prescriptive compliance requirements for Daylighting and Elemental Thermal Performance. However considerable consideration must also be given to passive solar heat gain to reduce the heating and cooling loads which can account for over a quarter of the building’s energy use. FenestraPro for Revit provides a balanced understanding between Thermal Performance (Heat Loss), Daylighting and Heat Gain.

Image 4 below shows a highly glazed south facing façade as overheating beyond the 25W/m2 recommendation. In this instance a reduction of the amount of glazing in the curtain wall should be considered, perhaps with an increase in the amount of spandrel.
Alternatively, a change of glazing specification to a glass with a lower Solar Heat Gain Coefficient (SHGC) or the introduction of shading could also be considered to reduce the heat gain, but when introducing shading devices consideration should also be given to the impact of daylighting.

Energy efficient architecture and regulations compliance with FenestraPro for Revit

To learn more about how FenestraPro for Revit can improve your design process, assist you with compliance with TEK17 and design better performing building please click here to register for our webinar on May 13th, 09:00 CET.

How to use energy guidelines and regulations with FenestraPro

How to use energy guidelines and regulations with FenestraPro0 Comments FenestraPro allows for management of the prescribed energy values As regulations get updated and new standards are approved, we think it is best to allow our users to control the standards they...

Stay Up to Date With The Latest News & Updates

For news and information on façade and high-performance building design

OFFICES
Ireland
+353 (0)1 661 9609
39 Leeson Street Lower, Dublin D02 PY89

UK
+44 (0)800 046 1521
86-90 Paul Street, London EC2A 4NE

USA
+1 212 726 2114
244 Fifth Avenue, Suite 2941, New York, NY 10001

WRITE TO OUR TEAM

For assistance with our software solutions:
support@fenestrapro.com

For sales and business development:
sales@fenestrapro.com

For all other matters:
info@fenestrapro.com